資源描述:

《外文翻譯--使用同步整流器的高效率開關(guān)電源單元英文版》由會員分享,可在線閱讀,更多相關(guān)《外文翻譯--使用同步整流器的高效率開關(guān)電源單元英文版(6頁珍藏版)》請?jiān)谘b配圖網(wǎng)上搜索。

1、High-Efficiency Switching Power Supply Unit with Synchronous Rectifier Rectification method Input voltage(V dc)Output voltage(V dc)Output current(A)Output power(W)Efficiencv(%)Y.Nakayash i k i,H.Sh imamor i,T.Satoh.T.Ohno Fujitsu Limited 4-1-1 Kami kodanaka,Nakahara-ku Kawasak i-c i ty,21 1-8588,Jap

2、an Schottky Synchronous(SBD)(Sync Rect)3.6 2.5/3.3 switchable 300 360 1080 1188 75 81 barrier diode rectifier 200-373 240-400 1.Introduction Power loss(W)Size W/H I D (mm)Power output per unit volume(W I Liter)Air flow(msl min)Weight(kg)Operating temperature This report describes an insulation type

3、switching power supply unit(DC/DC converter)for mainframe computers that uses a newly developed synchronous rectifying circuit for the secondary rectification component.Compared with conventional switching power supply units,this unit offers 6%higher processing efficiency,and power output per unit v

4、olume that has been boosted by 1.75 times.As a result,this unit provides high efficiency,low voltage,and high power output.Table 1 shows the summary of specifications.The unit is illustrated in Figure 1.360 278 9.1(Liter)5.7(Liter)120 1381 1200 60 I381 1250 119 208 8.5 5.3 2.4 1.5 0-45 0-45 Table 1

5、Specifications 2.Background In recent years,in LSI technology,there has been a shift from the use of transistortransistor logic(TTL)and emittercoupled logic(ECL)to the use of highly integrated complementary metal-oxide semiconductors S.Yamash ita,K.Fuoh i gam i,T.Yamamoto.Fujitsu Denso Limited 1-1 7

6、-3 Sakado,Takatsu-ku.Kawasak i-c i ty,21 3-8586,Japan(CMOS).At the same time,the logic component of CPUs,memories,and the like have been undergoing miniaturization at a relatively rapid pace.However,since it the power supply component is difficult to integrate,it is beginning to occupy most of the s

7、pace inside the mainframe.Until now,the water cooling method has been used to cool the logic component.Because the water cooling method is highly effective,it has been used in power supply unit too.However,using CMOS reduces the total amount of electric power used by the logic component,making the w

8、ater cooling unit(an expensive component)miniaturizing the power supply component unnecessary.Therefore,it has become all the more prohibitively expensive to use a water cooling unit just for the power supply component alone.It has become necessary to miniaturize the power supply unit by reducing th

9、e internal loss of the power supply and Figure 1 Previous(left)and new unit(right)0-7803-5069-3 198/$10.00 01998 IEEE 398 improving the processing efficiency of the unit.In addition,the powersupply voltage has been decreasing over time,from+5.0V to+3.3V,and then to+2.5V.Moreover,the loss of the seco

10、ndary rectification component made up of the Schottky barrier diode(SBD)has come to be relatively important.We therefore concluded that reducing the loss of the secondary rectification component would be the most important factor in the miniaturization process,and developed a switching power supply

11、unit that uses the synchronous rectifying circuit.3.Conventional circuit and loss analysis Figure 2 shows an outline of the switching supply circuit,and Figure 3 shows the result of the loss analysis.These figures indicate that the loss of the secondary rectification component occupies more than 40%

12、of the total loss.From the point of view of academic analysis,the results of this analysis suggested that using the synchronous rectifying circuit would lead to the improved processing efficiency shown in Figure 4.(7-F SBD Figure 2 Circuit of conventional unit 90 I I Q 80 W ic!.i.y.i.i.i.j 0,:a.r)v

13、0 1 2 3 45 6 Output voltage(VI Synchronous rectifier(Sync Rect)-SBD rectifier-Figure 4 Efficiency comparisons 4.Current circumstances of Sync Rect The fundamental concept of synchronous rectification has long existed.However,its practical application as a product has taken place only recently.Synchr

14、onous rectification in mobile equipment,beginning with laptop computers,is an important technology useful in extending the service life of the batteries that power such devices.Since it is relatively easy to control the circuit for the synchronous rectification operation when the non-insulation mode

15、 is used,thereby facilitating the switch to the use of ICs,synchronous rectification is used for the majority of DC/DC converters in CPUs.However,it is difficult to control the circuit for the synchronous rectification operation when the insulation method(required for the transformer)is used.Consequ

16、ently,the problems given below were encountered.Accordingly,the insulation method is only used with specific products.5.Problems encountered with Sync Rect Figure 5 shows the synchronous rectifying circuit generally used.There are a number of problems associated with this circuit.Moreover,the proces

17、sing efficiency was not as good as we had anticipated.Furthermore,another serious problem involving parallel operation was encountered.Figure 3 Power loss comparisons 399 INPUT-OUTPUT Figure 5 Circuit of previous synchronous rectifier 1)Insufficient driving of low side switch As Figure 6 illustrates

18、,when the main switches(Q01,2 in Figure 5)are turned off,the transformer is reset,resulting in the elimination of the generated voltage.Then,the low side switch Q2 is turned off,the current flows into the BD2(which is a body diode of Q2),leading to an increase in the loss.The Schottky barrier diode

19、D2 therefore needs to be mounted parallel with Q2 to increase the physical quantity.shortened and the amount of time during which the current flows into the D2 is extended.Since the processing efficiency achieved is almost the.same as that obtained with the SBD rectifying circuit,the positive effect

20、s of using the synchronous rectifying circuit are not very significant.2)Current detour at-parallel operation Figure 7 shows the units operating in parallel without using the blocking diode.When the main switches Q01,2 of one unit are turned off,the other unit outputs and applies the voltage to the

21、Q2 gate.As a result,one unit(Q2)is turned on.Then high current flows through the choke coil into the drain.This results in the Q2 being damaged and the output voltage being reduced.Also,when the time of the generation of the poweron and poweroff signal differ between the units,it causes the same sym

22、ptom to be generated,resulting in damage to the unit.Power supply f Other unit outputs I A 4 I Y output I:-I I:D2-f on Figure 7 Parallel operation F-7 -:I I Vt 0 plb-r.L.v g s q Low I+magnifL vgs ov:Power dissipation Figure 6 Waveforms of previous circuit When the range of the input voltage of the p

23、ower supply TofF-B Toff-A is broad and such input voltage is high,the reset time is Figure 8 2-types of gate waveforms 400 3)Delay of turning off time In most of the currently developed MOS-FET,the threshold voltage Vth of Vgs is reduced from 4 V to 2 V.As Figure 8 illustrates,when turning off Q1 an

24、d Q2 by OV gate voltage(slope A),the moderate part of the slope of the transient phenomena indicates the threshold.The loss is increased by the pass current that flows from the transformers due to the delay in the turning off time.4)Surge voltage Since the operation of synchronous rectifying circuit

25、 is bi-directional,the current of the choke coil L1 will not be discontinuous.When the load current is small,the L1 current flows in the reverse direction.Even the slightest delay in turning on the high side switch Q1 causes the current route of L1 to be cut,and the surge voltage to be generated,as

26、Figure 9 illustrates.As a result,Q1 and Q2 incur damage.I 3odv diode l-I+T Figure 9 Mechanism of producing a surge voltage 5)Circulating current in parallel operation When the units with the synchronous rectifying circuit are operated in parallel,if there is even the slightest difference in the outp

27、ut voltages,the large current flows from the higher output voltage unit into the lower output voltage unit.(This is illustrated in Figure 10.)The current is fed back to the primary side by the U2 inverter,after which it is once again returned to the secondary side by the U1 inverter.As a result,a la

28、rge circulating current flows between U1 and U2.Therefore,even with a light-load current,the loss generated in the unit is as extensive as that occurring with heavy loads.I12 Iout I1,1 I I IOUt=I2-I3 Figure 10 Root of circulating current 6.Solving problems and the new circuit The following describes

29、 a solution to the problems described in Section 5.Figure 11 shows the new synchronous rectifying circuit.Figure 13 is a diagram illustrating the configuration at parallel operation.1)Insufficient driving of low side switch Figure 11 shows Q2 and its driving switch Q3.As Figure 12 illustrates,when Q

30、01,2 are turned off and it generates the transformer reset voltage,Q3 is turned off and the positive voltage is applied to the Q2 gate through D3.When the reset is completed and the voltage is removed,D3 is turned off and the Q2 gate is disconnected.At this point,Q2 holds the electric charge in Ciss

31、 between th gate and the source and stays on.As a result,the Schottky barrier diode connected to Q2 in parallel becomes unnecessary.The synchronous rectifying circuit is able to minimize the loss on its own.t 2)Current detour at parallel operation Since both Q1 and Q2 use separate windings(N2 and N3

32、)for the drive as shown in Figure 1 1,a sneak current from other unit can be avoided,and they can operate in parallel.3)Delay of turning off time As shown in Figure 11,winding of transformer Q1 is directly connected between the gate and the source.When Q1 is turned off,a negative voltage can be appl

33、ied to the gate.In the transformer of Q2,positive voltage is-.I*Q4 is controlled by the current of L1 Figure 11 New circuit 4)Surge voltage When a current equivalent to the current of L1 is detected(the transformer current is detected in Figure ll),Q4 is turned off before the current of L1 or the eq

34、uivalent flows in the negative direction.By turning off Q4,the reverse voltage is applied to the Q2 gate and Q2 is turned off.BD2 then operates the rectification instead of Q2.Turning off Q2 before the choke coil current flows in the negative direction can stop the negative current of L1 and avoid t

35、he surge voltage.At this time,the forward drop of the rectifier increases from 4 3 on 0.2 V to 1 V.However,because the load current is small,no thermal failure occurs.0.Vds QO tLLr-Lr 0 Off Off Gs;A 0 vgs2 5)Circulating current in parallel operation The circulating current is eliminated by using the

36、 separate winding for the gate driving and stopping the synchronous rectifier in the cut-off area of the choke coil.7.Characteristics Figure 12 Waveform of new circuit Figure 14 shows the measured results of the internal loss and the efficiency of this new unit.As expected for the results in Figure

37、4,the loss is reduced by 23%and the efficiency is improved by 6%.generated when Q01,2 are turned on.Thereby,the gate charge is discharged through Q3.Then the reverse voltage is applied to the Q2 gate and Q1 is promptly turned off.(slope B in Figure 8)402 17-I I 31 I I I I I i I 90 80 E 60 50.$40 g 3

38、0 20 10 0 CI 70 Figure 13 Parallel operation 300 250-200$100 g U)150 f a 50 0 0 20 40 60 80 100 Load ratio(%)+Efficiency at 2.5V+Power loss at 2.5V+Efficiency at 3.3V-t Power loss at 3.3V Figure 14 Efficiency of new power supply unit 8.Conclusion We developed a new synchronous rectifying circuit tha

39、t can overcome all of the disadvantages that associated with conventional synchronous rectifying circuits.We have also embarked on the commercially production of an insulation type switching power supply unit that is a i r cooled,and offers high-efficiency,low voltage and high current output.However

40、,since the logic component of CPUs continues to undergo miniaturization at a rapid pace,the additional miniaturization of the power supply unit is more than ever in demand.Accordingly,we will,need to work on developing technologies that will allow us/to achieve higher levels of efficiency.9.Referenc

41、e Hirohiko Kim,Hiroyuki Satoh,Shigeharu Yamashita,Kazutoshi Fuchigami,WaterCooled Switching Power Supply INTELEC 89 Teruhiko Kohama,Tamotsu Ninomiya,Masahito Shoyama,Abnormal Phenomena Caused by Synchronous Rectifiers in Parallel-Module DC-DC Converter System TECHNICAL REPORT OF IEICE.EE97-53,CMP97-158(1998-01)403

展開閱讀全文
溫馨提示:
1: 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
2: 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
3.本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
5. 裝配圖網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

相關(guān)資源

更多
正為您匹配相似的精品文檔
關(guān)于我們 - 網(wǎng)站聲明 - 網(wǎng)站地圖 - 資源地圖 - 友情鏈接 - 網(wǎng)站客服 - 聯(lián)系我們

copyright@ 2023-2025  zhuangpeitu.com 裝配圖網(wǎng)版權(quán)所有   聯(lián)系電話:18123376007

備案號:ICP2024067431-1 川公網(wǎng)安備51140202000466號


本站為文檔C2C交易模式,即用戶上傳的文檔直接被用戶下載,本站只是中間服務(wù)平臺,本站所有文檔下載所得的收益歸上傳人(含作者)所有。裝配圖網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對上載內(nèi)容本身不做任何修改或編輯。若文檔所含內(nèi)容侵犯了您的版權(quán)或隱私,請立即通知裝配圖網(wǎng),我們立即給予刪除!